Product Overview Chapter 1

Mode of Operation

Bulletin 280E/281E

Full-Voltage Start

This method is used in applications requiring across-the-line starting, in which
full inrush current and locked-rotor torque are realized. The ArmorStart Bulletin
280E offers full-voltage starting and the Bulletin 281E offers full-voltage starting
for reversing applications.

Figure 3 - Full-Voltage Start

Bulletin 284E

Sensorless Vector Control

Sensorless vector control provides exceptional speed regulation and very high
levels of torque across the entire speed range of the drive. Features include:

• Autotune feature allows the Motor Controller to adapt to individual

motor characteristics.

• Able to develop high torque over a wide speed range and adapts to

individual motor characteristics.

• Embedded Variable Frequency Drive (VFD) control includes the Timer,

Counter, Basic Logic and StepLogic® functions which can reduce hardware
design costs and simplify control schemes.

• Integral PID (proportional, integral, differential) functionality enhances

application flexibility.

100%

Percent

Voltage

Time (seconds)

Advertising