Drive setup group (bulletin 284e only) – Rockwell Automation 284E ArmorStart with EtherNet/IP - User Manual User Manual

Page 160

Advertising
background image

160

Rockwell Automation Publication 280E-UM001B-EN-P – July 2012

Chapter 7 Bulletin 280E/281E/284E Programmable Parameters

Drive Setup Group (Bulletin 284E only)

Timer Status

The current value of the timer when
timer is enabled.

Parameter Number

126

Access Rule

GET

Data Type

UINT

Group

Drive Display

Units

0.1 sec

Minimum Value

0

Maximum Value

9999

Default Value

Read Only

StpLogic Status

When Parameter 138 (Speed
Reference) is set to "6" (StpLogic), this
parameter will display the current
step of StepLogic as defined by
Parameters 240…247 (StpLogic X).

Parameter Number

128

Access Rule

GET

Data Type

UINT

Group

Drive Display

Units

1

Minimum Value

0

Maximum Value

8

Default Value

Read Only

Torque Current

The current value of the motor torque
current.

Parameter Number

129

Access Rule

GET

Data Type

UINT

Group

Drive Display

Units

0.01

Minimum Value

0.00

Maximum Value

Drive Rated Amps x 2

Default Value

Read Only

Motor NP Volts

Set to the motor nameplate rated
volts.

Parameter Number

131

Related Parameters

104, 184, 185…187

Access Rule

GET/SET

Data Type

UINT

Group

Drive Setup

Units

1V AC

Minimum Value

20

Maximum Value

480V

Default Value

Based on Drive Rating

O

Stop drive before changing this
parameter.