Frequency time – Rockwell Automation 284E ArmorStart with EtherNet/IP - User Manual User Manual
Page 190

190
Rockwell Automation Publication 280E-UM001B-EN-P – July 2012
Chapter 7 Bulletin 280E/281E/284E Programmable Parameters
Figure 74 - EM Brk OFF Delay
StpLogic Time 0 (250)
StpLogic Time 1 (251)
StpLogic Time 2 (252)
StpLogic Time 3 (253)
StpLogic Time 4 (254)
StpLogic Time 5 (255)
StpLogic Time 6 (256)
StpLogic Time 7 (257)
Sets the time to remain in each step if
the corresponding Parameter 138
(Speed Reference) is set to “6”
(StpLogic), Parameter 240-247
(StpLogic x), digits 0…3 set to b, C, d
or E (Step after (StpLogic Time x).
Parameter Number
250…257
Related Parameters
138, 155, 171…177, 240…247
Access Rule
GET/SET
Data Type
UINT
Group
Drive Advanced Setup
Units
0.1 sec
Minimum Value
0.0 sec
Maximum Value
999.9 sec
Default Value
30.0 sec
EM Brk OFF Delay
Sets the time the drive will remain at
minimum frequency before ramping
to the commanded frequency and
energizing the brake coil relay when
Parameter 137 (Stop Mode) is set to
Option 8 or 9.
Parameter Number
260
Related Parameters
134, 137
Access Rule
GET/SET
Data Type
UNIT
Group
Drive Advanced Setup
Units
0.01 sec
Minimum Value
0.01 sec
Maximum Value
10 sec
Default Value
0.0 sec
Frequency
Time
Minimum Freq
260 [EM Brk Off Delay]
261 [EM Brk On Delay]
Stop
Commanded
Start
Commanded
EM Brk
De-Energized (On)
Drive Stops
EM Brk
Energized (Off)
Ramp A
cc
el
Ramp D
ecel