Bulletin 280E/281E/284E Programmable Parameters Chapter 7

129

Torque Current

Displays the current value of the motor torque current
as measured by the drive.

Read Only

Drive Display

284E

131

Motor NP Volts

Set to the motor name plate rated volts.

Based on Drive Rating

Drive Setup

284E

132

Motor NP Hertz

Set to the motor nameplate rated frequency.

60 Hz

Drive Setup

284E

133

Motor OL Current

Set to the maximum allowable current.

Based on Drive Rating

Drive Setup

284E

134

Minimum Freq

Sets the lowest frequency the drive will output
continuously.

0.0 Hz

Drive Setup

284E

135

Maximum Freq

Sets the highest frequency the drive will output
continuously.

60 Hz

Drive Setup

284E

136

Start Source

Sets the control scheme used to start the Bulletin 284E
ArmorStart.

5 = Comm Port

(RS485 (DSI))

Drive Setup

284E

137

Stop Mode

Sets the Valid Stop Mode for the Bulletin 284E
ArmorStart.

9 =

Ramp + EM Brk

Drive Setup

284E

138

Speed Reference

Sets the Valid Speed References for the Bulletin 284E
ArmorStart.

5 = Comm Port

Drive Setup

284E

139

Accel Time 1

Sets the rate of acceleration for all speed increases.

10.0 Secs

Drive Setup

284E

140

Decel Time 1

Sets the rate of deceleration for all speed decreases.

10.0 Secs

Drive Setup

284E

141

Reset To Defaults

Used to reset drive to factory default settings

0 = Ready/Idle

Drive Setup

284E

142

Option not valid for Bulletin 284E ArmorStart.

143

Motor OL Ret

Enables/Disables the Motor Overload Retention
function.

0 = Disabled

Drive Setup

284E

Table 28 - ArmorStart Common Parameters

Parameter

Number

Parameter Name

Description

Factory Default

Group

Controller

Table 29 - Parameter Descriptions

Parameter

Number

Parameter

Name

Description

Factory Default

Group

151…154

Digital In 1 Sel
Digital In 2 Sel
Digital In 3 Sel
Digital In 4 Sel

Selects the function for the digital inputs.

See Table 20.

Drive Advanced Setup

155

Relay Out Sel

Sets the condition that changes the state of the output
relay contacts.

0 = Ready/Fault

See Table 21.

Drive Advanced Setup

156

Relay Out Level

Sets the trip point for the digital output relay if the value of
Parameter 155 (Relay Out Sel) is 6, 7, 8, 10, 16, 17, 18, or 20.

0.0

Drive Advanced Setup

158

Reserved

— —

Drive Advanced Setup

159

Reserved

Drive Advanced Setup

161

Reserved

Drive Advanced Setup

162

Reserved

— —

Drive Advanced Setup

164

Reserved

Drive Advanced Setup

165

Option not valid for Bulletin 284E ArmorStart.

166

Option not valid for Bulletin 284E ArmorStart.