Rockwell Automation Publication 280E-UM001B-EN-P – July 2012

195

Bulletin 280E/281E/284E Programmable Parameters Chapter 7

44

OutB Net IdlValue

This parameter determines the state that Output B
assumes when the network is idle and Parameter 43
(OutB Net IdlState) is set to “0”.

0 = Open

User I/O Configuration

Common

45

Keypad Mode

This parameter selects if the keypad operation is
maintained or momentary.

0 = Maintained

Misc. Configuration

Common

46

Keypad Disable

This parameter disables all keypad function except for
the OFF and RESET buttons.

0 = Not Disabled

Misc. Configuration

Common

47

Set To Defaults

This parameter if set to 1 will set the device to the
factory defaults.

0 = No Operation

Misc. Configuration

Common

48

Drive Control

This parameter provides the status of drive parameters.

0

Drive I/O Configuration

284E

49

DrvIn Pr FltState

This parameter, in conjunction with Parameter 50
(DrvIn Pr FltValue), defines how the Drive Digital Inputs
1…4 will respond when a protection trip occurs.

0 =

Go to PrFlt Value

Drive I/O Configuration

284E

50

DrvIn Pr FltValue

This parameter determines the state of Drive Digital
Inputs 1…4, assumes when a trip occurs.

0 = Open

Drive I/O Configuration

284E

51

DrvIn Net FltState

This parameter, in conjunction with Parameter 52
(DrvIn Net FltValue), defines how the Drive Digital
Inputs 1…4 will respond when a network fault occurs.

0 =

Go to Fault Value

Drive I/O Configuration

284E

52

DrvIn Net FltValue

This parameter determines the state of Drive Digital
Inputs 1…4 when a network fault occurs and
Parameter 51 (DrvIn Net FltState) is set to “0”.

0 = OFF

Drive I/O Configuration

284E

53

DrvIn Net FItState

This parameter, in conjunction with Parameter 54
(DrvIn Net FItValue), defines how the Drive Digital
Inputs 1…4 will respond when a DeviceNet™ network
is idle.

0 =

Go to Fault Value

Drive I/O Configuration

284E

54

DrvIn Net FItValue

This parameter determines the state that Drive Digital
Inputs 1…4 assume when the network is idle and
Parameter 53 (DrvIn Net FItState) is set to “0”.

0 = OFF

Drive I/O Configuration

284E

55

High Speed Enaable

This parameter enable High Speed Inverter control thru
the terminal block.

0 = Disabled

Drive I/O Configuration

284E

56

Base Enclosure

Indicates the ArmorStart Base unit enclosure rating.

1

Basic Status

Common

57

Base Options

Indicates the options for the ArmorStart Base unit.

0

Basic Status

Common

58

Wiring Options

This parameter provides the Wiring Options.

0

Basic Status

Common

59

Starter Enclosure

This parameter provides the Starter Enclosure.

1

Basic Status

Common

60

Starter Options

This parameter provides the Starter Options.

0

Basic Status

Common

61

Last PR Fault

This parameter provides the Last PR Fault.

0 = None

Basic Status

Common

62

Warning Status

This parameter provides the Warning Status.

0

Basic Status

Common

63

Base Trip

This parameter provides the Base Module Trip Status.

0

Basic Status

Common

101

Phase A Current

This parameter provides the current of Phase A.

0

Starter Display

DOL

102

Phase B Current

This parameter provides the current of Phase B.

0

Starter Display

DOL

103

Phase C Current

This parameter provides the current of Phase C.

0

Starter Display

DOL

104

Average Current

This parameter provides the average current.

0

Starter Display

DOL

Table 28 - ArmorStart Common Parameters

Parameter

Number

Parameter Name

Description

Factory Default

Group

Controller