Chapter 7 Bulletin 280E/281E/284E Programmable Parameters
105
Therm Utilized
This parameter displays the % Thermal Capacity used.
0
Starter Display
DOL
106
FLA Setting
The motor’s full load current rating
See Table 19.
Starter Setup
DOL
107
Overload Class
Selects the overload class.
1 =
Overload Class 10
Starter Setup
DOL
108
OL Reset Level
Selects the % Thermal Capacity which an overload can
be cleared.
75
Starter Setup
DOL
101
Output Freq
Output frequency present at T1, T2 & T3 (U, V & W)
Read Only
Drive Display
284E
102
Commanded Freq
Value of the active frequency command
Read Only
Drive Display
284E
103
Output Current
Output current present at T1, T2 & T3 (U, V & W)
Read Only
Drive Display
284E
104
Output Voltage
Output voltage present at T1, T2 & T3 (U, V & W)
Read Only
Drive Display
284E
105
DC Bus Voltage
Present DC bus voltage level
Read Only
Drive Display
284E
106
Drive Status
Present operating condition of the drive.
Read Only
Drive Display
284E
107…109
Fault x Code
A code that represents a drive fault.
Read Only
Drive Display
284E
110
Process Display
The output frequency scaled by Parameter 199 (Process
Factor).
Read Only
Drive Display
284E
112
Control Source
Displays the source of the Start Command and Speed
Reference.
5 =
RS485 (DSI) Port
Drive Display
284E
113
Option not valid for Bulletin 284E ArmorStart.
114
Dig In Status
Status of the control terminal block digital inputs.
0
Drive Display
284E
115
Comm Status
Status of the communications ports
0
Drive Display
284E
116
Control SW Ver
Main Control Board software version for AC Drive.
Read Only
Drive Display
284E
117
Drive Type
Used by Rockwell Automation field service personnel.
Read Only
Drive Display
284E
118
Elapsed Run Time
Accumulated time drive is outputting power.
Read Only
Drive Display
284E
119
Testpoint Data
The present value of the function selected in Parameter
202 (Testpoint Sel).
Read Only
Drive Display
284E
120
Option not valid for Bulletin 284E ArmorStart.
121
Option not valid for Bulletin 284E ArmorStart.
122
Output Power
Output power present at T1, T2 & T3 (U, V & W).
Read Only
Drive Display
284E
123
Output Power Fctr
The angle in electrical degrees between motor voltage
and motor current.
Read Only
Drive Display
284E
124
Drive Temp
Present operating temperature of the drive power
section.
Read Only
Drive Display
284E
125
Counter Status
The current value of the counter when counter is
enabled.
Read Only
Drive Display
284E
126
Timer Status
The current value of the timer when timer is enabled.
Read Only
Drive Display
284E
128
StpLogic Status
When Parameter 138 (Speed Reference) is set to "6"
(StpLogic), this parameter will display the current
StepLogic profile as defined by Parameters 240-247
(StpLogic x).
Read Only
Drive Display
284E
Table 28 - ArmorStart Common Parameters
Parameter
Number
Parameter Name
Description
Factory Default
Group
Controller