Operation, Figure 2 - catalog number explanation for 284e – Rockwell Automation 284E ArmorStart with EtherNet/IP - User Manual User Manual

Page 18

Advertising
background image

18

Rockwell Automation Publication 280E-UM001B-EN-P - July 2012

Chapter 1 Product Overview

Figure 2 - Catalog Number Explanation for 284E

Operation

The ArmorStart Distributed Motor Controllers can operate three-phase squirrel-
cage induction motors as follows:

Bulletin 280E/281E:

up to 10 Hp (7.4 kW) at 480V AC

Bulletin 284E: up to 5 Hp (3.0 kW) at 480V AC

ArmorStart EtherNet/IP Controllers accept 24V DC control voltage. The
control voltage will provide power to inputs (unswitched) and outputs
(switched). Unswitched control voltage is used to ensure no loss of sensor or
other field input status under normal operation.

g

Short Circuit Protection (Motor

Circuit Protector)

Code

Description

10

10 A Rated Device

25

25 A Rated Device

a

Bulletin Number

Code

Description

284

VFD Starter

d

Torque Performance Mode

Code

Description

V

Sensorless Vector Control

and Volts per Hertz

i

Option 1

Code

Description

3

Hand/Off/Auto Selector

Keypad with Jog Function

h

Control and 3-Phase Power Connections / Motor Cable Connection

(CR: Conduit/Round Media) or (RR: Round/Round Media)

Code

Description

Control Power

3-Phase Power

Motor Cable

CR

blank

Conduit Entrance

Conduit Entrance

3 m, unshielded

cordset male 90°

CR

N

Conduit Entrance

Conduit Entrance

3 m, shielded

cordset male 90°

CR

W

Conduit Entrance

Conduit Entrance

No cable

RR

blank

Round Media

(Male Receptacle)

Round Media

(Male Receptacle)

3 m, unshielded

cordset male 90°

RR

N

Round Media

(Male Receptacle)

Round Media

(Male Receptacle)

3 m, shielded

cordset male 90°

RR

W

Round Media

(Male Receptacle)

Round Media

(Male Receptacle)

No cable

284

E – F

V D2P3 D – 10 – CR – Option 1 – Option 2 – Option 3

a

b

c

d

e

f

g

h

i

j

k

b

Communications

Code

Description

E

EtherNet/IP

c

Enclosure Type

Code

Description

F

Type 4 (IP67)

e

Output Current

380…480V

Code

Description

D1P4

1.4 A, 0.4 kW, 0.5 Hp

D2P3

2.3 A, 0.75 kW, 1.0 Hp

D4P0

4.0 A, 1.5 kW, 2.0 Hp

D6P0

6.0 A, 2.2 kW, 3.0 Hp

D7P6

7.6 A, 3.3 kW, 5.0 Hp

j

Option 2

Code

Description

DB

blank DB Brake Connector

DB1

blank

Connectivity to IP67

DB Resistor

SB

blank

Source Brake

Contactor

SB

W

No cable

k

Option 3

Code

Description

EMI

EMI Filter

OC

Output Contactor

f

Control Voltage

Code

Description

Z

24V DC

Advertising