Rockwell Automation 284E ArmorStart with EtherNet/IP - User Manual User Manual

Page 186

Advertising
background image

186

Rockwell Automation Publication 280E-UM001B-EN-P – July 2012

Chapter 7 Bulletin 280E/281E/284E Programmable Parameters

PID Diff Rate

Sets the value for the PID differential
component when the PID mode is
enabled by Parameter 232 (PID Rel
Sel).

Parameter Number

236

Access Rule

GET/SET

Data Type

UINT

Group

Drive Advanced Setup

Units

0.01 (1/sec)

Minimum Value

0.00 (1/sec)

Maximum Value

99.99 (1/sec)

Default Value

0.01 (1/sec)

PID Setpoint

Provides an internal fixed value for
process setpoint when the PID mode
is enabled by Parameter 232 (PID Ref
Sel).

Parameter Number

237

Access Rule

GET/SET

Data Type

UINT

Group

Drive Advanced Setup

Units

0.1%

Minimum Value

0.0%

Maximum Value

10.0%

Default Value

0.0%

PID Deadband

Sets the lower limit of the PID output.

Parameter Number

238

Access Rule

GET/SET

Data Type

UINT

Group

Drive Advanced Setup

Units

0.1%

Minimum Value

0.0%

Maximum Value

10.0%

Default Value

0.0%

PID Preload

Sets the value used to preload the
integral component on start or
enable.

Parameter Number

239

Access Rule

GET/SET

Data Type

UINT

Group

Drive Advanced Setup

Units

0.0 Hz

Minimum Value

0.0 Hz

Maximum Value

400.0 Hz

Default Value

0.0 Hz