Appendix B CIP Information

I/O Assemblies

The following table summarizes the Assembly instances that are supported in the
ArmrorStart EtherNet/IP Product:

➊ These assemblies are selectable on Inverter Type ArmorStart units only.

Instances 3 and 52 are required by the ODVA Motor Starter Profile. When used
as an EtherNet/IP Class 1 connection point, the I/O data attribute is simply
passed through the bridge.

Instance 3

This is the required output (consumed) assembly.

Instance 52

This is the required input (produced) assembly.

Instance Type

Description

3

Consumed

Required ODVA Consumed Instance

52 Produced

Required

ODVA Produced Instance

150

Produced

Default Bulletin 280E/281E Produced Assembly

151

Produced

Default Bulletin 284E Produced Assembly

162

Consumed

Default Consumed Instance for DOL and Reversing Starters

166

Consumed

Default Consumed Instance for Inverter type Starters

191

Consumed

Empty assembly for Input Only I/O Connection

192

Consumed

Empty assembly for Listen Only I/O Connection

Instance 3 ODVA Starter

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

Run Fwd

Instance 52 ODVA Starter

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Running

Fault