Chapter 7 Bulletin 280E/281E/284E Programmable Parameters

Figure 73 - Skip Frequency Band

Stall Fault Time

Sets for the fault time that the drive
will remain in stall mode before a
fault is issued.
0 = 60 sec (Default)
1 = 120 sec
2 = 240 sec
3 = 360 sec
4 = 480 sec
5 = Flt Disabled

Parameter Number

221

Access Rule

GET/SET

Data Type

UINT

Group

Drive Advanced Setup

Units

Minimum Value

0

Maximum Value

5

Default Value

0

Var PWM Disable

Stop drive before changing this
parameter.
Enables/disables a feature that varies
the carrier frequency for the PWM
output waveform defined by
Parameter 191 (PWM Frequency).
0 = Enabled
1 = Disabled
Disabling this feature when low
frequency condition exists may result
in IGBT stress and nuisance tripping.

Parameter Number

224

Related Parameters

191

Access Rule

GET/SET

Data Type

UINT

Group

Drive Advanced Setup

Units

Minimum Value

0

Maximum Value

1

Default Value

0

Torque Perf Mode

Stop drive before changing this
parameter.
Enables/disables sensorless vector
control operation.
0 = V/Hz
1 = Sensrls Vect

Parameter Number

225

Related Parameters

184…187, 227

Access Rule

GET/SET

Data Type

UINT

Group

Drive Advanced Setup

Units

Minimum Value

0

Maximum Value

1

Default Value

1

Frequency

Time

Skip Frequency

Command
Frequency

Drive Output
Frequency

2x Skip
Frequency Band