Rockwell Automation Publication 280E-UM001B-EN-P – July 2012

Appendix B CIP Information

Instance 1 of the Identity Object will contain the following attributes:

➊ Instance 1 only

The following common services will be implemented for Instance 1. Service
requests to other instances are serviced through the bridge.

The Type 0 and 1 reset service types will reset the Control Module. The
EtherNet/IP module will perform the Type 0 or 1 reset on itself.

Attribute ID

Access Rule

Name

Data Type

Value

1 Get

Vendor

UINT

1

2 Get

Device

Type

UINT

22

3

Get

Product Code

UINT

Starter Rating specific

4 Get

Revision
Major Revision
Minor Revision

Structure of:

USINT

USINT

See table above.

5 Get

Status

WORD

Bit 0…0 = Not Owned; 1 = Owned by Master
Bit 2…0 = Factory Defaulted; 1 = Configured
Bit 8 - Minor Recoverable fault
Bit 9 - Minor Unrecoverable fault
Bit 10 - Major Recoverable fault
Bit 11 - Major Unrecoverable fault

6

Get

Serial Number

UDINT

Unique number for each device

7 Get

Product Name
String Length
ASCII String

Structure of:

USINT

STRING

Product Code specific

8

Get

State

USINT

Returns the value "3 = Operational"

9 Get

Configuration
Consistency Value

UINT "Module

FRS"

102

Get Build

Number

UDINT

Build

number of EtherNet/IP Module firmware.

Service Code

Implemented for:

Service Name

Class

Instance

0x01 Yes

Yes

Get_Attributes_All

0x05 No

Yes

Reset

0x0E Yes

Yes Get_Attributes_Single