Ethernet link object, Class code 0x00f6 – Rockwell Automation 284E ArmorStart with EtherNet/IP - User Manual User Manual

Page 305

Advertising
background image

Rockwell Automation Publication 280E-UM001B-EN-P – July 2012

305

CIP Information Appendix B

Ethernet Link Object

CLASS CODE 0x00F6

The following class attributes will be supported.

One instance of the Ethernet Link Object will be supported with the following
instance attributes.

Attribute ID

Access Rule

Name

Data Type

Value

1

Get

Revision

UINT

3

2

Get

Max Instance

UINT

2

3

Get

Number of Instances

UINT

2

Attribute ID

Access Rule

Name

Data Type

Value

1

Get

Interface Speed

UDINT

10 or 100 Mbit/Sec

2

Get

Interface Flags

DWORD

See ENet/IP Spec

3

Get

Physical Address

ARRAY of 6 USINTs

MAC Address

4 Get Interface

Counters

Struct of:

In Octets

In Ucast packets
In NUcast packets
In Discards
In Errors
In Unknown Protos
Out Octets
Out Ucast packets
Out NUcast packets
Out Discards
Out Errors

5 Get Media

Counters

Struct of:

Alignment Errors

FCS Errors
Single Collisions
SQE Test Errors
Deferred Transmits
Late Collisions
Excessive Collisions
MAC Transmit Errors
Carrier Sense Errors
Frame Too Long
MAC Receive Errors

6 Get/Set Interface

Control

Struct of:

Control Bits

Forced Interface Speed

7 Get

Interface

Type

USINT

8 Get

Interface

State

USINT

9 Get/Set

Admin

State

USINT

10 Get

Interface

Label

SHORT_STRING

Instance 1: Port 1
Instance 2: Port 2