Discrete input point object, Class code 0x0008, Discrete output point object – Rockwell Automation 284E ArmorStart with EtherNet/IP - User Manual User Manual

Page 288: Class code 0x0009

Advertising
background image

288

Rockwell Automation Publication 280E-UM001B-EN-P – July 2012

Appendix B CIP Information

Discrete Input Point Object

CLASS CODE 0x0008

The following class attributes are currently supported for the Discrete Input
Point Object:

Four instances of the Discrete Input Point Object are supported. All instances
contain the following attributes.

The following common services will be implemented for the Discrete Input Point
Object.

Discrete Output Point Object

CLASS CODE 0x0009

The following class attributes are supported.

Four instances of the Discrete Output Point Object are supported for DOL/
Reverser units. Ten instances are supported for Drive units. The following table
summarizes the DOP instances.

Attribute ID

Access Rule

Name

Data Type

Value

1

Get

Revision

UINT

2

2

Get

Max Instance

UINT

4

Attribute ID

Access Rule

Name

Data Type

Value

3

Get

Value

BOOL

0 = OFF, 1 = ON

115

Get/Set

Force Enable

BOOL

0 = Disable, 1 = Enable

116

Get/Set

Force Value

BOOL

0 = OFF, 1 = ON

Service Code

Implemented for:

Service Name

Class Instance

0x0E Yes Yes Get_Attribute_Single

0x10 No Yes Set_Attribute_Single

Attribute ID

Access Rule

Name

Data Type

Value

1 Get

Revision

UINT

1

2

Get

Max Instance

UINT

4 or 10

Advertising