Bulletin 280 and 281 armorstart fault bits – Rockwell Automation 284E ArmorStart with EtherNet/IP - User Manual User Manual

Page 321

Advertising
background image

Rockwell Automation Publication 280E-UM001B-EN-P – July 2012

321

Using DeviceLogix Appendix C

The following table contains the status bit definitions for ArmorStart 280D and
281D units:

Bulletin 280 and 281 ArmorStart Fault Bits

The screen capture below shows how to choose fault bits in the ladder editor.

The following table contains the fault bit definitions for Bulletin 280D and
281D ArmorStart units:

Status Bit Declaration

0

=

Tripped

1 = Running Fwd

2 = Running Rev

3 = Ready

4 = Net Ctl Status

5 = At Reference

6 = Keypad Hand

7 = HOA Status

8 = 140M On

9 = Explicit Msg Cnxn Exists

10 = IO Cnxn Exists

11 = Explicit Cnxn Fault

12 = IO Cnxn Fault

13 = IO Cnxn Idle

14 = Current Flowing

15 = Keypad Hand Direction

Fault Bit Declaration

0 = Short Circuit

1 = Overload

2 = Phase Loss

3 = Control Power

4 = IO Fault

5 = Over Temp

6 = Phase Imbalance

7 = DNet Power Loss

8

=

EEprom

9 = HW Flt

10 = PL Warning

11 = CP Warning

12 = IO Warning

13 = Phase Imbal Warn

14 = DN Warning

15 = HW Warning

Advertising