Selection Criteria

Object

Description

• Slot/Port

Select the Slot and port for which data is to be displayed or configured. Slot 0 is

the base unit. You must have configured at least one router interface before

configuring or displaying data for a PIM-DM interface, otherwise an error

message will be displayed.

Configurable Data

Object

Description

• Interface Mode

Select enable or disable from the pulldown menu to set the administrative status

of PIM-DM for the selected interface. The default is disable.

• Hello Interval

Enter the number of seconds between PIM hello messages transmitted from the

selected interface. The default value is 30. Valid values are from (10 to 3600) .

• Submit button

Send the updated configuration to the router. Configuration changes take effect

immediately. These changes will not be retained across a power cycle unless a

save is performed.