2. Starting via External Signal Selection

(1) Flow

chart

When the READY signal turns ON, the RDY
lamp (green) on the controller front panel will
illuminate.

Input a desired program number as a BCD code
from the external device.*

Input a start signal from the external device.

When the program is run, the number of the
started program will be shown in the CODE
display area of the controller front panel.

If an emergency-stop signal was input from the
external device or a controller error occurred,
the controller will turn off the servo power (the
RDY lamp will turn off).

*1 You can input program numbers as binary

codes by setting I/O parameter 30 (input
function selection 000) to “2.” (This
parameter has been set to “1,” or BCD code
specification, at the factory.)

Note: On a controller with increased memory size (with gateway function), up to 128 programs can be

stored. Take note, however, that only program Nos. 1 to 79 can be started by BCD code
specification. To start program Nos. 80 to 128 using BCD codes, use the auto program start
function or program start command “EXPG.”

Select a desired program number externally and then input a start signal.

Controller

Power ON

READY signal ON

Program number

confirmed?

N

N

N

N

Y

Y

Y

N

N

Y

N

Y

Start signal
confirmed?

Program run

Emergency-stop

signal confirmed?

Controller

error?

Servo OFF

ALARM signal ON

Alarm output

Emergency

stop input

External start

input

Program number

input

Ready output

External device

Power ON

READY signal

confirmed?

Various I/O

processing

Program number

specification

Start signal ON

Emergency stop

switch ON?

Emergency-stop

signal ON

ALARM signal

confirmed?

ALARM

processing

Y