z PAPR (Set push-motion approach distance, speed)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

PAPR

Distance

Speed CP

[Function]

Set the operation to be performed when a PUSH command is executed.
Set the distance (push-motion approach distance) over which push-motion approach
operation (torque-limiting operation) will be performed in operand 1 (in mm), and set the
speed (push-motion approach speed) at which push-motion approach operation (torque-
limiting operation) will be performed in operand 2 (in mm/sec).
The push-motion approach distance specified in operand 1 may contain up to three decimal
places, while the speed specified in operand 2 cannot contain any decimal place.

[Example] PAPR

100

30

MOVP

10

PUSH

11

Set the push-motion approach distance in a PUSH
command to 100 mm and the push-motion approach
speed to 30 mm/sec.

(Note)

When an OVRD command is used, the push-motion approach speed is clamped by the
minimum speed of 1 mm/sec.
(The minimum speed does not guarantee reliable push motion operation. If low-speed
push-motion approach is needed, confirm the operation on the actual machine by
considering the effects of mechanical characteristics, etc.)

Position origin

Push-motion approach distance

Start position of push-motion
approach operation
(torque-limiting operation)

Z

Y

X