27

Part 1 Installation

[14] General RS232C port

connector 1

Channel 1 of the two-channel RS232C port provided for connection of
general RS232C equipment.
(Refer to I/O parameter Nos. 201 to 203.)

[15] General RS232C port

connector 2

Channel 2 of the two-channel RS232C port provided for connection of
general RS232C equipment.
(Refer to I/O parameter Nos. 213 to 215.)

General RS232C Connector Specifications

Item Overview

Details

Connector

D-sub, 9 pin (DTE)

XM2C-0942-502L (OMRON)

Connector name

S1/S2

Maximum wiring
distance

10 M

At 38400 bps

Interface standard

RS232C

Connected unit

AT-compatible PC,
etc.

Half-duplex communication

Connection cable

PC-AT standard 232C cross-
cable

1

In

(CD)

(Carrier detection: Not used)

Terminal
assignments

2

In

RD

Received data (RXD)

3

Out

SD

Transmitted data (TXD)

4

Out

ER

Equipment ready (DTR)

5

In SG

Signal

ground

6

In

DR

Data set ready (DSR)

7

Out

(RS)

(Request to send (RTS): Not
used)

8

In

(CS)

(Clear to send (CTS): Not used)

9

NC

Not

used

Use a cross-cable to connect to the RS232C port of a PC.

[16] Installation position of

field network board

This is where a Fieldbus interface module is installed. In this example, this
position is left unoccupied (no module is installed).

[17] Optional board

An optional field network board is installed. A DeviceNet board is installed in

this example.

[18] Expansion I/O board

(optional)

Optional expansion I/O boards are installed in the example.