Noise control measures and grounding – IAI America XSEL-QX User Manual

Page 37

Advertising
background image

13

Part 1 Installation

4. Noise Control Measures and Grounding

(1) Wiring and power source

PE on the power terminal block is used for protective grounding. Provide Class D grounding from this
terminal.
Use a grounding cable with a wire size of 1.0 mm

2

(#AWG17) or more, which should not be smaller

than the AC power cable.

[1] Notes on wiring method

Use twisted cables for the AC power cable and 24-VDC external power cable. Wire the controller cables
separately from lines creating a strong electric field such as power circuit lines (by not bundling them
together or placing in the same cable duct).
If you wish to extend the motor cable or encoder cable beyond the length of each supplied cable, please
contact IAI’s Technical Service Section or Sales Engineering Section.

(2) Noise-elimination

grounding

Provide dedicated grounding for the FG and PE.

Class D

grounding

Metal enclosure

X-SEL

Controller

Other

equipment

Do not connect as above.

X-SEL

Controller

Other

equipment

Class D grounding

(protective grounding)