10. Axis Movement by Input Waiting and Output of Complete Signal

Description

How to perform an input waiting process and output a processing complete signal is explained.

Flow Chart

Application Program

End of program

Output 310 turns

OFF

Input 11

Output 310 turns

ON

Move to P1

Input 10

Start

Example of Use

The actuator waits until input port 10 turns ON, upon which it will
move to P1.
The actuator waits until input port 11 turns ON, upon which it will
move to P2.
A complete signal for movement to P1 is provided by 310, while a
complete signal for movement to P2 is provided by 311.

Output 311 turns

ON

Move to P2

Set the speed to 100 mm/sec.

Wait for input 10 to turn ON.

Move to P1.

Output 310 turns ON.

Wait for input 11 to turn ON.

Output 310 turns OFF.

Move to P2.

Output 311 turns ON.

End of program