Part 4 Commands

z PUSH (Move by push motion in CP operation)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

PUSH

Target

position

number

Prohibited PE

[Function]

Perform push-motion operation until the target position specified in operand 1 is reached.
The axes move in a normal mode from the position origin to the push-motion approach start
position as determined by a PAPR command, after which push-motion approach operation
(toque-limiting operation) will be performed. The speed of push-motion approach operation
(toque-limiting operation) is determined by the push-motion approach speed specified by a
PAPR command. If the output field is specified, the output will turn ON when a contact is
confirmed, and turn OFF when a missed contact is detected.
The speed and acceleration of movement from the position origin to the push-motion
approach start position will conform to the values specified by a VEL, ACC or DCL
command or position data.

The push force can be adjusted using “Driver-card parameter No. 38, Push torque limit at
positioning” (default value: 70%).

(Note 1)

Among SCARA axes, a PUSH command only moves the Z-axis. If multiple axes are
specified, an “Error No. C91, Multiple push-axes specification error” will generate.

(Note 2)

A push-motion approach speed exceeding the maximum speed permitted by the system
will be clamped at the maximum speed. (The maximum system speed is not the maximum
practical speed. Determine a practical speed by considering the impact upon contact, etc.)

Position origin

Push-motion approach distance

Target position

Start position of push-motion approach operation
(torque-limiting operation)

Z

X

Y