13 structural if – IAI America XSEL-QX User Manual

Page 285

Advertising
background image

261

Part 4 Commands

1.13 Structural IF

z IF…… (Structural IF)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

IF

……

Variable

number

Data CP

[Function]

Compare the content of the variable specified in operand 1 with the value specified in
operand 2, and proceed to the next step if the condition is satisfied.
If the condition is not satisfied, the program will proceed to the step next to the
corresponding ELSE command, if any, or to the step next to the corresponding EDIF
command.
If the input condition is not satisfied and the IF

…… command is not executed, the program

will proceed to the step next to the corresponding EDIF.
A maximum of 15 nests are supported when IS

…… and DW…… are combined.

IF

……

EQ

Operand 1 = Operand 2

NE

Operand 1 z Operand 2

GT

Operand 1 > Operand 2

GE

Operand 1 t Operand 2

LT

Operand 1 < Operand 2

LE

Operand 1 d Operand 2

[Example

1]

SVON

1111

Set the current arm system in variable 99.

PRDQ

1

100

Read the current X coordinate into variable 100.

CPNE

99

0

600

600

IFEQ

99

1

If the arm system is indeterminable, the arm
system whose flag 600 is turned OFF will be
determined. If this arm system is also
indeterminable, the operation will end.

IFGE

100

0

MOVP

1

If the X coordinate is 0 or greater:
Move the axis to position No. 1 in PTP mode.

ELSE

MOVP

2

Move the axis to position No. 2 in PTP mode.

EDIF

ELSE

IFGE

100

0

MOVP

3

If the X coordinate is 0 or greater:
Move the axis to position No. 3 in PTP mode.

ELSE

MOVP

4

Move the axis to position No. 4 in PTP mode.

EDIF

EDIF

EXIT

If the current arm system is the right arm and the X coordinate is 0 or greater, the axis will
move to position No. 1; if the X coordinate is below 0, the axis will move to position No. 2.
If the current arm system is the left arm and the X coordinate is 0 or greater, the axis will
move to position No. 3; if the X coordinate is below 0, the axis will move to position No. 4.

(Note)

Using a GOTO command to branch out of or into an IF

……-EDIF syntax is prohibited.