IAI America XSEL-QX User Manual

Page 306

Advertising
background image

282

Part 4 Commands

z WRIT (Write)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

WRIT

Channel

number

Column

number

CC

(NOTE 1)

[Function]

Write the character string in the column specified in operand 2 to the channel specified in
operand 1.
The operation will end when the character specified by a SCHA command is written.
Either a local or global column can be specified.

[Example]

SCHA

10

Set LF (= 10) as the end character.

OPEN

1

Open

channel

1.

WRIT

1

2

Write the character string in column 2 to channel 1 until
LF is written.

CLOS

1

Close the channel.

As long as a standard SIO port (channel 1 or 2) is open, a task other than the one that
opened the port can be used to execute (send) a WRIT command. Accordingly, if a READ
command is executed in a port-opening task and then a WRIT command is executed in
other task, the response from the other side can be received without delay after the
command is sent from the X-SEL.

(Note 1)

CP for channels other than 1 and 2.

Return code of the WRIT command (channels 1 and 2 only)
The return code is stored in a local variable. Variable number can be set by “Other parameter No. 24.” The
default variable number is 99.
0: WRIT completed successfully
1: WRIT timeout (the timeout value is set by a TMRW command)
2: WRIT timer cancelled (the wait status is cancelled by a TIMC command)
3 and 4: For future extension
5: WRIT factor error (program abort error) (cannot be recognized by SEL commands)
6: WRIT task ended (program end request, etc.) (cannot be recognized by SEL commands)

Advertising