Aborting of operation 2 (stop) – IAI America XSEL-QX User Manual

Page 424

Advertising
background image

400

Appendix

17. Aborting of Operation 2 (STOP)

Description

Cause the moving axis to decelerate a stop and cancel the remaining operation of the axis. (STOP)

How to Use

Implement an abort using a STOP command issued from other program. (Multi-tasking mode)
Use an axis pattern to specify the axis you want to abort.

Example of Use 1

STOP command
Main program

Aborting control program

If “STOP 11” is executed while “MOVL 1” is still being executed, “MOVL 1” will be cancelled and
operation will continue from “MOVL 2.”

Example of Use 2

Main program

Aborting control program

If “STOP 10” is executed while “MOVP 1” is still being executed, only axis 2 corresponding to “MOVP
1” will be cancelled. Both axes 1 and 2 will operate from “MOVP 2.”

Caution

In the operation being performed is a CP operation (interpolation operation) started by MOVL, etc., the
operation of all axes will be cancelled regardless of the axis pattern specified by the STOP command.

Time

o

Input port 20 ON

Remaining
operation

Speed

o

This operation is cancelled.

Start an aborting program.

Wait for an abort input.

Abort axes 1 and 2.

Wait for an abort input.

Abort axis 2.

Advertising
This manual is related to the following products: