Various methods are available to switch between programs, depending on the purpose of programs.
The representative methods are explained below.

External

start

Program switching

Program

Single-tasking

EXIT command

Multi-tasking

EXPG command

First, the program switching methods are largely divided into switching by external start and switching
by application program.

(1) External start method

Refer to Chapter 1, “Operation” (Starting via External
Signal Selection) in Part 2, “Operation.”

(2) Program

method

{ Single-tasking

Executing an EXIT command (end program) at the end of each program will end the program and
cause the system to return to the condition immediately after the power is turned on. However,
since the home position is retained, another program can be started by an external start input with
the corresponding program number specified.

{ Multi-tasking

Creating a management program and executing EXPG commands (start other program) will allow
a series of programs to be run in parallel.