IAI America XSEL-QX User Manual

Page 49

Advertising
background image

25

Part 1 Installation

[11] Panel window

This window consists of a 4-digit, 7 segment LED display and five LED

lamps that indicate the status of the equipment. For the information shown
on the display, refer to 2, “Explanation of Codes Displayed on the Panel
Window” or the “Error Code Table.”

Meanings of Five LEDs

Name Status when the LED is lit

RDY

CPU ready (program can be run)

ALM

CPU alarm (system down level error), CPU hardware error

EMG

Emergency stop has been actuated, CPU hardware error, power
system hardware error

PSE

Power system hardware error

CLK

System clock error

[12] Mode switch

This alternate switch with lock is used to command a controller operation

mode. To operate the switch, pull it toward you and tilt.
Tilting the switch upward will select MANU (manual mode), while tilting it
downward will select AUTO (auto mode). Teaching can be performed only in
the MANU mode, but auto program start is not enabled in the MANU mode.
* If you are using a QX type controller, connect the supplied dummy plug to

the teaching connector [9] during the AUTO mode.

[13] Standard I/O connector This connector consists of a 50 pin flat connector and comprises 32 input

/

16

output DIOs.

Overview of Standard I/O Interface Specifications

Item Description

Connector name

I/O

Connector Flat

connector, 50 pin

Power supply

Supplied from connector pin Nos. 1 and 50

Input

32 points (including general purpose and dedicated
inputs)

Output

16 points (including general purpose and dedicated
outputs)

Connected to

External PLC, sensor, etc.

Advertising