IAI America XSEL-QX User Manual

Page 437

Advertising
background image

413

Appendix

(3) Parameter Settings

The SIO channel numbers and specifications are set as follows according to the factory-set parameters.

For advanced settings, set the following parameters sequentially:
Channel 1

o I/O parameter Nos. 201 to 203

Channel 2

o I/O parameter Nos. 213 to 215

I/O Parameter Settings (Reference)

No.

Parameter name

Default value

Input range

Unit

201

Attribute 1 of SIO channel 1 opened to user
(mount standard)

28100001H

0H to FFFFFFFFH

None

213

Attribute 2 of SIO channel 1 opened to user
(mount standard)

28100001H

0H to FFFFFFFFH

None

Bits 28 to 31:

Baud rate type (0: 9.6, 1: 19.2, 2: 38.4, 3: 57.6, 4: 76.8, 5: 115.2 kbps)

Bits 24 to 27:

Data length (7 or 8)

Bits 20 to 23:

Stop bit length (1 or 2)

Bits 16 to 19:

Parity type (0: None, 1: Odd, 2: Even)

Bits 12 to 15:

For future extension

Bits 8 to 11:

For future extension

Bits 4 to 7:

For future extension

Bits 0 to 3:

Use selection (0: Do not use, 1: Use)

Channel 1

Specifications
Baud rate: 38.4 kbps
Data length: 8
Stop bit: 1
Parity type: None
Communication mode: RS232

Baud rate

0: 9.6 kbps 1: 19.2 kbps 2: 38.4 kbps 3: 57.6 kbps 4: 76.8 kbps 5: 115.2 kbps

Data length: 7, 8

Stop bit length: 1, 2

Parity type: 0: None, 1: Odd, 2: Even

For future extension

For future extension

For future extension

Use selection: 0 (Do not use, 1: Use)

Channel 2

Advertising
This manual is related to the following products: