IAI America XSEL-QX User Manual

Page 479

Advertising
background image

455

Appendix

Axis-Specific Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

93

Zone 3 MIN of linear
movement axis

0 -99999999

~

99999999

Reference only

for SCARA axes

(axes 1 to 4)

0.001 mm

Valid only when MAX > MIN. * Must be inside
the range for at least 3 msec.
* Valid for linear movement axes (axes 5 and 6

(6-axis type)) only.
(Main application version 0.15 or later)

94

Zone 3 output number for
linear movement axis

0

0 ~ 899

Reference only

for SCARA axes

(axes 1 to 4)

Physical output port or global flag (Output is
invalid if “0” is input; multiple specification is
invalid)
* Valid for linear movement axes (axes 5 and 6

(6-axis type)) only.
(Main application version 0.15 or later)

95

Zone 4 MAX of linear
movement axis

0 -99999999

~

99999999

Reference only

for SCARA axes

(axes 1 to 4)

0.001 mm

Valid only when MAX > MIN. * Must be inside
the range for at least 3 msec.
* Valid for linear movement axes (axes 5 and 6

(6-axis type)) only.
(Main application version 0.15 or later)

96

Zone 4 MIN of linear
movement axis

0 -99999999

~

99999999

Reference only

for SCARA axes

(axes 1 to 4)

0.001 mm

Valid only when MAX > MIN. * Must be inside
the range for at least 3 msec.
* Valid for linear movement axes (axes 5 and 6

(6-axis type)) only.
(Main application version 0.15 or later)

97

Zone 4 output number for
linear movement axis

0

0 ~ 899

Reference only

for SCARA axes

(axes 1 to 4)

Physical output port or global flag (Output is
invalid if “0” is input; multiple specification is
invalid)
* Valid for linear movement axes (axes 5 and 6

(6-axis type)) only.
(Main application version 0.15 or later)

98~
116

(For extension)

0

~

117 PIG

0

Reference only

For adjustment by the manufacturer

118 PDG

0

Reference only

For adjustment by the manufacturer

119 PFSG

50,
50,
50,
50,

0,

0

0 ~ 100

* Change is prohibited unless instructed by the

manufacturer.

120 PFF

10

0 ~ 100

* Change is prohibited unless instructed by the

manufacturer.

121~

130

(For extension)

0

~

131 For future extension

(Change prohibited)

0 0H

~

FFFFFFFFH

132 For future extension

(Change prohibited)

0 0H

~

FFFFFFFFH

133 For future extension

(Change prohibited)

0 0H

~

FFFFFFFFH

134 Maximum

PTP

acceleration of SCARA
axis

2700,
5400,

160,

11000,

0,

0

1 ~ 99999999

0.01 G,

deg/sec

2

Set in units of 0.01 G only for axis 3 (Zb). Set in
deg/sec

2

for other SCARA axes.

135 Maximum

PTP

deceleration of SCARA
axis

2700,
5400,

160,

11000,

0,

0

1 ~ 99999999

0.01 G,

deg/sec

2

Set in units of 0.01 G only for axis 3 (Zb). Set in
deg/sec

2

for other SCARA axes.

Advertising
This manual is related to the following products: