z STOP (Stop movement)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

STOP

Axis

pattern

Prohibited CP

[Function]

Decelerate an axis to a stop.

(Note 1)

A STOP command can be used with all active servo commands other than a SVOF
command.

(Note 2)

With SCARA, all axes will be decelerated to a stop regardless of the axis pattern.

(Note 3)

A STOP command only issues a deceleration-stop command (operation stop) and does not
wait for stopping to complete. Issuing other servo commands to a decelerating axis will
either become invalid or generate an “axis duplication error,” etc.
Set a timer, etc., in the program so that the next servo command will be issued after a
sufficient deceleration-stop processing time elapses.
Even when a STOP command is to be is issued to an axis currently stopped, provide a
minimum interval of 0.1 second before the next servo command is issued.

[Example 1]

STOP

1

Decelerate SCARA axes to a stop.

[Example 2]

STOP

110000

Decelerate linear movement axes (axes 5 and 6) to a
stop.