432

Appendix

I/O Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

48 Output function selection

302

2

0 ~ 20

0: General-purpose output
1: Emergency-stop output (ON)
2: Emergency-stop output (OFF)

49 Output function selection

303

0

0 ~ 5

0: General-purpose output
1: AUTO mode output
2: Output during automatic operation (Other

parameter No. 12)

50 Output function selection

304

0

0 ~ 5

0: General-purpose output
1: Output when all valid linear movement axes are at

the home (= 0)

* Valid only for the 6-axis type.

(Main application version 0.15 or later)

2: Output when all valid linear movement axes have

completed home return (coordinates are
confirmed)

* Valid only for the 6-axis type.

(Main application version 0.15 or later)

3: Output when all valid linear movement axes are at

the preset home coordinates

* To move an absolute-encoder linear movement

axis to coordinate 0 or to the preset home
coordinates, use a MOVP command instead of a
HOME command.

* Valid only for the 6-axis type.

(Main application version 0.15 or later)

51 Output function selection

305

0

0 ~ 5

0: General-purpose output
1: For future extension
2: Output when axis-1 servo is ON (System monitor

task output)

3: For future extension

52 Output function selection

306

0

0 ~ 5

0: General-purpose output
1: For future extension
2: Output when axis-2 servo is ON (System monitor

task output)

3: For future extension

53 Output function selection 307

0

0 ~ 5

0: General-purpose output
1: For future extension
2: Output when axis-3 servo is ON (System monitor task

output)

3: For future extension

54 Output function selection 308

0

0 ~ 5

0: General-purpose output
1: For future extension
2: Output when axis-4 servo is ON (System monitor task

output)

3: For future extension

55 Output function selection 309

0

0 ~ 5

0: General-purpose output
1: For future extension
2: Output when axis-5 servo is ON (F-ROM 16-Mbit

version only)

3: For future extension
* The synchro slave axis will follow the synchro master

axis.

* Valid only for the 6-axis type.

56 Output function selection 310

0

0 ~ 5

0: General-purpose output
1: For future extension
2: Output when axis-6 servo is ON (F-ROM 16-Mbit

version only)

3: For future extension
* The synchro slave axis will follow the synchro master

axis.

* Valid only for the 6-axis type.

57 Output function selection 311

0

0 ~ 5

0: General-purpose output, 1 to 3: For future extension

58 Output function selection 312

0

0 ~ 5

0: General-purpose output ,1 to 3: For future extension

59 Output function selection 313

1

0 ~ 5

0: General-purpose output
1: System-memory backup battery voltage-low warning

level or lower