Movement by position number specification – IAI America XSEL-QX User Manual

Page 425

Advertising
background image

401

Appendix

18. Movement by Position Number Specification

Description

Read an external BCD code input as a position number to move the actuator.

How to Use

Use an INB command to read a position number as a BCD code via an input port. A position number
consisting of up to three digits can be specified.

Flow Chart Input

assignment

Output

Application Program

Start

Default setting

Start input

Read a BCD

Movement complete

signal turns OFF

Move to the

specified position

number

Movement complete

signal turns ON

Port

Description

Completion of movement by 303

1 Start

input

15 Position

specification

1

16 Position

specification

2

17 Position

specification

4

18 Position

specification

8

19 Position

specification

10

20 Position

specification

20

21 Position

specification

40

22 Position

specification

80

23 Position

specification

100

24 Position

specification

200

25 Position

specification

400

26 Position

specification

800

Set a speed.

Destination of GOTO

Wait for a start input.

Read a position number.

Moving complete signal turns OFF

Move to the position number.

Movement complete signal turns ON

Jump to TAG1.

Advertising
This manual is related to the following products: