IAI America XSEL-QX User Manual

Page 454

Advertising
background image

430

Appendix

I/O Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

30 Input function selection

000

1

0 ~ 5

0: General-purpose input
1: Program start signal (ON edge) (Input ports 007 to

013: BCD-specified program number)

2: Program start signal (ON edge) (Input ports 007 to

013: Binary-specified program number)

3: Program start signal (ON edge)

(Input port Nos. 008 to 014: BCD specified program
number)
(Main application version 0.36 or later)

Note: The function of “I/O parameter No. 44: Input

function selection 014” (drive-source cutoff reset
related) is assigned to “I/O parameter No. 37:
Input function selection 007,” while the function
of “I/O parameter No. 43: Input function selection
013” (error reset, program start specified
program number) is assigned to “I/O parameter
No. 44: Input function selection 014.” To specify
a program number in 7 bits, all of the functions
from “I/O parameter No. 38: Input function
selection 008” to “I/O parameter No. 44: Input
function selection 014” must be set to “1:
Program start specified program number.”

4: Program start signal (ON edge)

(Input port Nos. 008 to 014: Binary specified program
number) (Main application version 0.36 or later)

Note: he function of “I/O parameter No. 44: Input

function selection 014” (drive-source cutoff reset
related) is assigned to “I/O parameter No. 37:
Input function selection 007,” while the function
of “I/O parameter No. 43: Input function selection
013” (error reset, program start specified
program number) is assigned to “I/O parameter
No. 44: Input function selection 014.” To specify
a program number in 7 bits, all of the functions
from “I/O parameter No. 38: Input function
selection 008” to “I/O parameter No. 44: Input
function selection 014” must be set to “1:
Program start specified program number.”

* If this parameter is used as a program start signal,

turn ON the signal for at least 100 msec so that the
program will start without fail.

* In the case of a controller with increased memory

size (with gateway), only program Nos. 1 to 79 can
be started via BCD specification, while only
program Nos. 1 to 127 can be started via binary
specification. Program No. 128 cannot be started
using this signal.

31 Input function selection

001

0

0 ~ 5

0: General-purpose input
1: Software reset signal (restart) signal (1 second ON)

* If continued operation is specified as the action

upon emergency stop, enable the software reset
signal (to provide a means of canceling the
operation).

32 Input function selection

002

0

0 ~ 5

0: General-purpose input
1: Servo ON

* ON edge: Equivalent to the all-valid-axis servo ON

command, OFF edge: Equivalent to the all-valid-
axis servo OFF command (A minimum interval of
1.5 seconds is required) (Must be executed in non-
operating condition)

33 Input function selection

003

1

0 ~ 5

0: General-purpose

input

1: General-purpose input (Start the auto-start program

upon power-ON reset/software reset in the AUTO
mode)

2: Auto-start program start signal (ON edge: Start, OFF

edge: Abort all operations/programs (excluding the
I/O processing program at operation/program abort))

* If this parameter is used as an auto-start program

start signal, turn ON the signal for at least 100
msec so that the program will start without fail.