Part 4 Commands

z DFIF (Dedicated SCARA command: define coordinates of simple interference check zone)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

DFIF

Interference

check zone

number

Position number

(Consecutive two

positions will be used)

CP

[Function]

Set the consecutive two position data starting from the position number specified in
operand 2 as the coordinate data defining the simple interference check zone specified in
operand 1.
The position data specified in operand 2 will be set as definition coordinates 1 of the simple
interference check zone, while the next position data will be set as definition coordinates 2.
If the axis patterns of the consecutive two position data do not match, an "Error No. C30:
Axis pattern error" will generate.

(Note 1)

The simple interference check zone is a dedicated SCARA function.

(Note 2)

The definition coordinates of simple interference check zone are always treated as data on
the base coordinate system (load coordinate system No. 0). Therefore, to provide position
data for valid definition coordinates for the purpose of executing a DFIF command, the data
must be set on the base coordinate system beforehand.

(Note 3)

After the definition coordinates of simple interference check zone are changed, it will take 5
msec before the check result reflects the new settings.

(Note 4)

GRP commands are invalid with respect to this command.

[Example 1]

DFIF

1

170