IAI America XSEL-QX User Manual

Page 477

Advertising
background image

453

Appendix

Axis-Specific Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

67 Short-cut

control

selection

for rotational movement
axis (linear movement
axis)

0

0 ~ 5

Reference only

for SCARA axes

(axes 1 to 4)

0: Do not select, 1: Select (Valid only in the index
mode AND when an incremental encoder is used)
* Valid for linear movement axes (axes 5 and 6

(6-axis type)) only.

(Main application version 0.12 or later)

68 Mode selection for linear

movement axis (linear
movement axis)

0

0 ~ 5

Reference only

for SCARA axes

(axes 1 to 4)

0: Normal, 1: Infinite-stroke mode (Note:
Positioning boundary applies. This parameter can
be specified only when an incremental encoder is
used.)
* Valid for linear movement axes (axes 5 and 6

(6-axis type)) only.

(Main application version 0.12 or later)

69 (For

extension)

0

~

70 For future extension

0

Reference only

For adjustment by the manufacturer

71 For future extension

0

Reference only

For adjustment by the manufacturer

72 For future extension

(Change prohibited)

0

Reference only

DRVVR

For adjustment by the manufacturer

73 For future extension

(Change prohibited)

0

Reference only

DRVVR

For adjustment by the manufacturer

74 For future extension

0

Reference only

For adjustment by the manufacturer

75 For future extension

0

Reference only

For adjustment by the manufacturer

76 For future extension

(Change prohibited)

0 0H

~

FFFFFFFFH

(Change

prohibited)

0: P21 = Phase-Z evacuation distance at

incremental home return

P12 = Ideal phase-Z position coordinate

1: Automatically acquire P32 even when P33 = 0.

P33 = 0 “= Actual distance”

P21 = Offset travel distance at home return

P12 = Coordinate after offset travel at home

return

P26 is invalid (to make adjustment easy).

77 Synchro S pulse of linear

movement axis

0,
0,
0,
0,
3,

3

0 ~ 99999

Reference only

for SCARA axes

(axes 1 to 4)

Pulse

* Valid for linear movement axes (axes 5 and 6

(6-axis type)) only.

(Main application version 0.12 or later)

78 Maximum

takeoff

command amount

0

-3000 ~ 3000

0.001 mm

Maximum lift command amount before brake
unlock (Input with sign)
(Suppression of momentary drop upon servo ON
when a heavy object is placed)
* Important: Input using the same sign as the

rising coordinate direction. (0.100
mm to 0.500 mm in absolute value
as a guideline)

* The servo-ON check time (axis-specific

parameter No. 30) must also be extended
(approx. 1000 to 1500 msec) to provide a
sufficient time for rise-direction torque to
follow. (This setting is valid only when a brake
is equipped.)

79 Actual takeoff check

distance

5

0 ~ 3000

0.001 mm

Absolute value input

80 Maximum

forced-feed

range of linear movement
axis

0

0 ~ 9999

Reference only

for SCARA axes

(axes 1 to 4)

0.001 mm

For reduction of settling time.
(Invalid range if “0” is set)
(Approx. 1.000 mm as a guideline)
* Valid for linear movement axes (axes 5 and 6

(6-axis type)) only.

(Main application version 0.12 or later)

81 Minimum

forced-feed

range of linear movement
axis

0,
0,
0,
0,

200,

200

0 ~ 9999

Reference only

for SCARA axes

(axes 1 to 4)

0.001 mm

* Valid for linear movement axes (axes 5 and 6

(6-axis type)) only.

(Main application version 0.12 or later)

Advertising