IAI America XSEL-QX User Manual

Page 134

Advertising
background image

110

Part 3 Controller Data Structure

2.2 Controller with Increased Memory Size (with Gateway Function)

(Other parameter No. 20 = 0 (System-memory backup battery not installed))

The programs, parameters, symbols and positions are read from the flash memory at restart. The data in
the main CPU memory will remain the same as the original data before edit unless the edited data are
written to the flash memory. The controller always operates in accordance with the data in the main CPU
memory (excluding the parameters).
Note: SEL global data cannot be retained if the backup battery is not installed.

Data edited on the PC

or teaching pendant

Data will be retained while the power

is on and cleared upon reset

Data will be retained even after the

power is turned off

PC

software,

TP

Transfer

Transfer

Transfer

Main CPU RAM memory

Programs

Parameters (other than

slave parameters)

Symbols

Positions (X-SEL axis)

(No. 1 to 2000)

Coordinate system data

Slave card

parameters

(Variable driver

parameters)

Slave card parameters

(Encoder parameters,

etc.)

Write to flash memory

Write to flash memory

Transfer upon reset

Transfer upon reset

Transfer upon reset

Transfer upon reset

Transfer upon reset

Main CPU flash memory

Slave card memory

Slave card memory

SEL global data (flags,

variables, strings)

Error lists

Transfer

Write to flash memory

Transfer upon reset

Transfer

User-data backup

memory

(Positions (RC axis))

Slave card parameters

(Fixed driver parameters

and power-supply

parameters)

(Cannot be changed)

Advertising