68

Part 1 Installation

[4] Enable

operation

x I/O parameter No. 24, bits 0 to 3 = 0: The RDYOUT output (system I/O) is SYSRDY (PIO trigger

program operation enabled) and the hardware is normal
(emergency stop is not actuated and no hardware errors are
detected).

x I/O parameter No. 44 = 0:

The drive-source cutoff reset input is not yet used.

x I/O parameter No. 47 = 3:

Output function 301 = READY output (PIO program operation
enabled and no errors of cold start level or higher have
occurred).

200-VAC control power

Normal CPU start

I/O output signal: Port No. 301
Ready output

Rdy (system I/O)

SDN (system I/O)

EMG1, EMG2 (system I/O)

ENB1, ENB2 (system I/O)

Occurrence of secret level error

Occurrence of message level error

Occurrence of operation cancellation level error

Occurrence of cold start level error

Occurrence of system shutdown level error

Enable SW = ON

Enable SW = OFF