Part 4 Commands

Operation type in the output field
CC:

Command was executed successfully, ZR: Operation result is zero,

PE:

Operation is complete, CP: Command part has passed, TU: Time up

EQ:

Operand 1 = Operand 2, NE: Operand 1

z Operand 2,

GT:

Operand 1 > Operand 2, GE: Operand 1

t Operand 2,

LT:

Operand 1 < Operand 2, LE: Operand 1

d Operand 2

Command Page Condition

Operand 1

Operand 2

Output

Function

E

ECMD 319

Optional

1

Axis number

CC

Get motor current value

ECMD 319

Optional

2

Axis number

CC

Get home sensor status

ECMD 320

Optional

3

Axis number

CC

Get overrun sensor status

ECMD 320

Optional

4

Axis number

CC

Get creep sensor status

ECMD 321

Optional

250

Axis pattern

CC

Set torque limit/detection time for torque limit
over error

EDDO

265

Prohibited Prohibited

Prohibited

CP

Declare end of DO

EDIF

263

Prohibited Prohibited

Prohibited

CP

Declare end of IF

EDPA

293

Prohibited Prohibited

Prohibited

CP

Declare end of palletizing setting

EDSL

269

Prohibited Prohibited

Prohibited

CP

Declare end of SLCT

EDSR

171

Prohibited Prohibited Prohibited

CP

End

subroutine

ELSE

263

Prohibited Prohibited

Prohibited

CP

Declare execution destination when IF
command condition is not satisfied

EOR

153

Optional

Exclusive OR operand
variable

Operand

ZR

Logical exclusive OR

EXIT

172

Optional

Prohibited

Prohibited

CP

End program

EXPG

170

Optional

Execution program
number

(Execution program
number)

CC Start

program

EXSR

170

Optional

Execution subroutine
number

Prohibited CP

Execute

subroutine

F

FMIO

166

Optional

Format type

Prohibited

CP

Set IN (B)/OUT (B) command format

G

GACC

190

Optional

Variable number

Position number

CP

Get acceleration data

GARM

273

Optional

Variable number

Prohibited

CP

Get current arm system

GDCL

191

Optional

Variable number

Position number

CP

Get deceleration data

GOTO

169

Optional

Jump destination tag
number

Prohibited CP

Jump

GRP

205

Optional

Valid axis pattern

Prohibited

CP

Set group axes

GTIF 226

Optional

Interference check zone
number

Position number

CP

Get definition coordinates of simple
interference check zone (SCARA only)

GTTL 213

Optional

Tool coordinate system
number

Position number

CP

Get tool coordinate system definition data
(SCARA only)

GTTM

157

Optional

Time assignment
variable

Prohibited CP

Get

time

GTWK 216

Optional

Load coordinate system
number

Position number

CP

Get load coordinate system definition data
(SCARA only)

GVEL

189

Optional

Variable number

Position number

CP

Get speed data

H

HOLD

206

Optional

(Input port to pause)

(HOLD type)

CP

Declare port to pause

HOME

228

Optional

Home return axis pattern Prohibited

PE

Return to home (Linear movement axis only)

I

IF

……

261

Optional

Comparison variable Comparison

value

CP

Compare [EQ, NE, GT, GE, LT, LE]

INB

163

Optional

Head I/O, flag

Conversion digits

CC

Input BCD (8 digits max.)

IN

162

Optional

Head I/O, flag

End I/O, flag

CC

Input binary (32 bits max.)

IS

…… 262

Optional

Column

number

Column number,
character literal

CP Compare

strings

ITER

265

Optional Prohibited

Prohibited CP

Repeat

DO

J

J

…W…

235

Optional

Axis operation pattern

Start I/O, flag

PE

Jog [FN, FF, BN, BF]

L

LEAV

264

Optional

Prohibited

Prohibited

CP

Pull out from DO

LEFT 218

Optional

Prohibited

Prohibited

PE

Change current arm system to left arm
(SCARA only)
(Arm 2 may operate if the current arm system
is the opposite arm)

LET

141

Optional

Assignment variable

Assigned value

ZR

Assign

Advertising