IAI America XSEL-QX User Manual

Page 523

Advertising
background image

499

Appendix

(In the pan

el wind

ow, the thre

e digits aft

er “E” in

dicate an erro

r nu

mber.

)

Error No.

Error name

Description, ac

tion, etc.

B1D

Ethernet non-open err

or

An attempt

w

a

s made to use

a channel not

yet opened by

ow

n task.

B1E

Ethernet multi

p

le WRIT ex

ecu

tion error

WRIT

commands

w

ere execut

ed simult

aneousl

y

i

n

multiple tasks for the same

channel, or a

WRIT

command had fai

led (due to a communication error,

etc.) and

then

w

a

s retri

ed

w

it

h

out exec

uting a C

L

OS command

o

O

PEN command first.

B1F

Ethernet jo

b bu

s

y

error

An attempt

w

a

s made to star

t a ne

w

proc

ess

w

h

en the Ethernet mailbox

control job

w

a

s bus

y.

B20

Ethernet no

n-i

nitial

izatio

n de

vice use err

or

An attempt

w

a

s made to use

the Ethernet s

ystem

w

h

en Ethernet dev

ice ini

tializa

tion

w

a

s not

y

e

t complete. Check I/O parameter

Nos. 123 to 159, 14, 15, etc.,

depending

on the pur

pos

e of use.

B21

Ethernet IP ad

dress error

An error

w

ill

ge

nerat

e under the follo

w

ing conditions

duri

ng normal use.

When IP address (H) (first octet) through IP

addr

ess (L) (fourth octet) are given

as

IP_H, IP_MH, IP_ML an

d IP_L, the error conditions

are des

cribed

as follow

s

:

IP_H

d

0 or IP_H = 127 or IP_H > 255

or IP_MH < 0 or IP_MH > 255

or IP_ML < 0 or IP_ML > 255

or IP_L

d

0 or IP_L

t

25

5

Check I/O parameter Nos. 132 to 135, 149 to

152, and 154 to 157, the IP addr

ess of

connection des

tination specifi

ed by an IPCN

command i

n

an integer variable, or the

like.

B22

Ethernet port n

u

mber error

An error

w

ill

ge

nerate if

o

w

n

port number < 1025, or o

w

n

port number > 65535, or

o

w

n port number duplicati

on, or connection-

destination por

t number for cli

ent

d

0, or

connection-

des

tination port number for client

> 65535, or co

nnecti

on-d

estin

ation

port number for server < 0, or

connection-

des

tination port number for server

>

65535 is satisfied.

Check I/O parameter Nos. 144 to 148, 159, 153, and 158, the port num

ber

of

connection des

tination specifi

ed by an IPCN

command i

n

an integer variable, or the

like.

B44

Load mass setting error

T

he load mass

exceeds the m

a

ximum lo

adi

n

g

capac

it

y

of th

e robot. Check

the set

mass.

B4B

“Load mass change prohibite

d

w

h

ile servo i

s

in use” error

T

he load mass

currentl

y

use

d

b

y

the serv

o system ca

nnot b

e

chan

ge

d.

B70

Checksum

error in coordinate

s

y

stem de

finition data

T

he flash

ROM data is damaged.

* SCARA only

.

B71

Coordinate s

y

s

tem number er

ror

T

he

coordinate s

y

stem num

ber is invali

d.

* SCARA only

.

B72

Coordinate s

y

s

tem type err

or

T

he coordinate

s

y

stem t

y

pe is

invali

d.

* SCARA only

.

Advertising
This manual is related to the following products: