Part 1 Installation

[9] Teaching

connector The teaching interface connects IAI’s teaching pendant or a PC to enable

operation and setting of your equipment from the teaching pendant/PC. The
physical interface consists of a RS232C system based on a 25 pin D-sub
connector. The signal level conforms to RS232C, and a desired baud rate
(up to 115.2 kbps) can be selected depending on the program. RS232C
communication is possible only when the mode switch (12) is set to the
MANU position.
You can also use an ANSI teaching pendant equipped with an ANSI-
compliant double-action enable switch. Whether the controller supports an
ANSI teaching pendant or IAI’s standard teaching pendant can be set using
the selector switch (8) provided above the teaching pendant connector. (P
type only)
* With Q-type controllers, connect the supplied dummy plug to the teaching

connector during the AUTO mode.

Interface Specifications of Teaching Serial Interface

Item Overview

Details

Connector

DSUB-25

XM3B-2542-502L (by Omron)

Connector name

T.P.

Teaching connector

Communication
method

RS232C-compliant,
start-stop
synchronous half-
duplex communication

Signal assignments conform to the
RS232C DTE terminal layout. Assign
dedicated control lines to undefined
lines, etc.

Baud rate

Up to 115.2 kbps

Half-duplex communication speeds of
up to 115.2 kbps are supported.

Maximum wiring
distance

10M

At 38.4 kbps

Interface standard

RS232C

Connected unit

Dedicated teaching
pendant

IAI’s standard teaching pendant for
X-SEL, or ANSI teaching pendant

Connection cable

Dedicated cable

Power supply

5 VDC or 24 VDC

A multi-fuse (MF-R090) is installed to
protect each line against short
current (the fuse will trip with currents
of between 1.1 A and 2.2 A).

Protocol X-SEL

teaching

protocol

The connector supports the X-SEL-
J/K teaching pendant interface
protocol.

Emergency-stop
control

Series emergency-
stop relay drive (24 V)

An emergency-stop relay drive line is
provided in the interface connector.
This line is connected in series with
other emergency-stop contact.
Two independent emergency stop
input circuits are provided as a
redundant safety design.

Enabling control

Enable switch line (24
V)

A line for connecting an enable
switch is provided as an operator
interlock. Two independent enable
input circuits are provided as a
redundant safety design.

[12] Mode switch

AUTO/MANU switch

Whether or not the teaching pendant
can be used is set by the
AUTO/MANU mode switch. The
controller establishes a handshake
with the teaching pendant only when
this switch is set to the MANU mode.
Note, however, that the teaching
pendant displays the monitor screen
regardless of the AUTO/MANU
setting.