392

Appendix

9. Output of Home Return Complete Signal (for Linear Axes)

Description

Output a signal to confirm completion of home return (Incremental specification or quasi-absolute
specification)
X-SEL controllers can output a home return complete signal via setting of an I/O parameter, but the
following explains how to output a home return complete signal in a program using a general-purpose
output.
When a general-purpose output is used, once the output is turned ON it will remain ON even after the
program ends or other program is started. (The output will turn OFF under certain conditions such as
actuation of an emergency stop. It is also possible to hold the output using an I/O parameter (I/O
parameter No. 70 or 71)).

Example of Use

a. Output a home return complete signal.

b. Use a home return complete signal to prevent the actuator from performing home return again after it

has been completed once.

c. Use the output field instead of a BTON command.

Reference

If I/O parameter No. 50 is set to “2,” output port No. 304 can be used as a home return complete output
(dedicated output).

Caution:

Take note that if you are using the linear servo actuator LSAS-N10/N15 of quasi-absolute
type, after completing a home return operation following power on the actuator moves in a
range of approx. 16 mm from the stopped position to confirm the current position.

Execute home return.
General-purpose output (arbitrary)

Execute home return if output 303 is OFF.
Output a home return complete signal.

The same processes implemented by
the above two steps are performed.