Part 3 Controller Data Structure

2. When the System Memory Backup Battery is Not Used

2.1 Controller without Increased Memory Size

Other parameter No. 20 = 0 (System memory backup battery not installed)

The programs, parameters, symbols and positions are read from the flash memory at restart. The data in
the main CPU memory will remain the same as the original data before edit unless the edited data are
written to the flash memory. The controller always operates in accordance with the data in the main CPU
memory (excluding the parameters).
Note: SEL global data cannot be retained if the backup battery is not installed.

Data edited on the PC

or teaching pendant

Data will be retained while the power is

on and cleared upon reset

Data will be retained even after the

power is turned off

PC

software,

TP

Transfer

Transfer

Transfer

Main CPU memory

Programs

Parameters (other than

slave parameters)

Symbols

Positions

Coordinate system data

Slave card parameters

(driver card

parameters)

Slave card parameters

(encoder parameters)

Write to flash memory

Write to flash memory

Transfer upon reset

Transfer upon reset

Transfer upon reset

Transfer upon reset

Transfer upon reset

Transfer

Main CPU flash memory

Slave card memory

Slave card memory

Slave card parameters

(driver card parameters

(cannot be changed))

SEL global data (flags,

variables, strings)

Error lists