IAI America XSEL-QX User Manual

Page 505

Advertising
background image

481

Appendix

(In the pan

el wind

ow, the thre

e digits aft

er “E” in

dicate an erro

r nu

mber.

)

Error No.

Error name

Description, ac

tion, etc.

400

Mounted-SIO unopen error (S)

An attempt

w

a

s made to use

a channel that is not open.

401

Mounte

d-SIO in-use err

or

An attempt

w

a

s made to ope

n

a chan

nel that has already

been

opened by

other task.

402

Mounted-SIO unopen error (M

)

An attempt

w

a

s made to use

a

channel not opened by

the applicable task

.

403

Mounted-SIO duplic

ate WRIT

executi

on error

WRIT

commands

w

e

re execut

ed simult

aneousl

y

by

multipl

e tasks for the same

channel.

404

Mounte

d-SIO unuse

d chan

ne

l selectio

n error

An attempt

w

a

s made to

use

a channel spec

ified as “not used” by

a par

am

eter. Che

ck

I/O parameter Nos. 201, 213, etc.

406

Flash bus

y res

et timeout

Error

erasing/

w

riting the flas

h ROM

407

Control c

onstant table manag

ement inform

ation mismatch

error

T

he managem

ent informati

on regardi

ng the

control constant table is invali

d. If this error

occurs

w

h

en the control

ler is s

tarted, the

cont

rol constant table may need t

o

be

updated.

408

Control c

onstant table ID error

T

he control constant table ID

is invalid.

409

Encoder control constant error

(po

w

er-sou

rce voltage control

)

An encoder control cons

tant relating to po

w

e

r-source voltage c

ontrol is i

n

v

a

lid. T

he

encoder po

w

e

r-

source volt

age cannot be ad

justed (the e

n

c

oder p

o

w

e

r

w

ill

be supp

lie

d

w

it

hout voltage adjustment).

40A

Encoder po

w

e

r-

source volt

age calcul

ation er

ror

T

he encoder po

w

e

r-source v

o

ltage cannot be ad

justed (th

e enco

der po

wer

w

ill

be

suppl

ie

d

w

itho

ut voltage a

d

ju

stment). Check

the “motor/enc

oder configur

ation

information” in

driver par

amet

er No. 26 and encoder par

am

eter No. 11.

40B

Speed control

paramet

er calc

ulation error

Check driv

er parameter Nos.

38, 39, 40, 43,

44, 45, etc.

40C

Vision s

y

stem i

n

itial

ization inc

omplet

e error

Initializ

ation of the visio

n s

y

st

em is not

yet complet

e. Chec

k the input p

o

rt

number

setting in all-axis paramet

er No. 88, and

al

so check if the vision s

y

stem has been

initialized, among others.

40D

Vision s

y

stem r

e

sponse timeout error

Co

mmunication respo

nse from the vision s

ystem cannot be confirmed. Check bits 4-7

of I/O parameter No. 129, I/O parameter Nos.

160 to 164,

all-axis param

eter Nos. 62,

63 and 89, and also check if the vision s

y

stem is sendi

ng data in respons

e to imagi

ng

commands, among others.

40E

T

racking parameter error

Invalid tracking parameter. Che

ck if the tracking par

ameters

in all-

ax

is par

ameter Nos.

61 to 95, etc., are set correctl

y

. If convey

or

tracking

adjustment has not been com

pleted

successfully

, perform conveyor tracking adjustment first.

40F

T

racking load c

oordi

nate s

y

stem error

T

he current definition data for

the loa

d coord

inate s

y

stem is different from the defi

nition

data for the load coordinate s

ystem used in convey

or tracking adjustment. Before

performing trac

king action, select the load c

o

ordin

ate s

y

stem used in conv

e

y

or tracking

adjustm

ent.

410

T

racking s

y

stem initial

ization i

n

compl

ete error

Initializ

ation

of the vision s

y

st

em is not

yet complet

e. Chec

k if the track

ing s

y

stem t

y

pe

specified in all-

axis par

ameter

No. 61 is not set to “Do not use s

y

stem.”

411

T

racking s

y

stem in use by

other task error

T

he tracking s

y

stem is bein

g u

s

ed by

other ta

sk. Use the tracking s

y

stem

w

ithin

the

same task.