IAI America XSEL-QX User Manual

Page 164

Advertising
background image

140

Part 4 Commands

Operation type in the output field
CC:

Command was executed successfully, ZR: Operation result is zero,

PE:

Operation is complete, CP: Command part has passed, TU: Time up

EQ:

Operand 1 = Operand 2, NE: Operand 1

z Operand 2,

GT:

Operand 1 > Operand 2, GE: Operand 1

t Operand 2,

LT:

Operand 1 < Operand 2, LE: Operand 1

d Operand 2

Command Page Condition

Operand 1

Operand 2

Output

Function

S

SPUT

287

Optional

Column number

Data

CP

Set character

SQR

150

Optional

Root assignment
variable

Operand ZR

Root

SSPG

175

Optional

Pause program number

(Pause program
number)

CC Pause

program

STOP

237

Optional

Axis stop pattern

Prohibited

CP

Decelerate and stop axis

STR

288

Optional

Column number

Data

CC

Convert character string; decimal

STRH

289

Optional

Column number

Data

CC

Convert character string; hexadecimal

SUB

143

Optional

Minuend variable

Subtrahend

ZR

Subtract

SV

……

229

Optional

Operation axis pattern

Prohibited

PE

Servo [ON, OF]

SYST

272

Optional

Variable number

Prohibited

CP

Get system status

T

TAG

169

Prohibited Declaration tag number

Prohibited

CP

Declare jump destination

TAN

148

Optional

Tangent assignment
variable

Operand ZR

Tangent

TIMC

156

Optional

Program number

Prohibited

CP

Cancel waiting

TIMR

373

Optional

Local flag number

Timer setting

CP

Timer relay for ladder

TIMW

155

Optional

Wait time

Prohibited

TU

Wait

TMLI 257

Optional

Position

number Prohibited

PE

Move relatively between positions on tool
coordinate system via interpolation (SCARA
only)

TMPI 256

Optional

Position

number Prohibited

PE

Move relatively between positions on tool
coordinate system (SCARA only)

TMRW

281

Optional

Read timer setting

(Write timer setting)

CP

Set READ timeout value

TPCD

317

Prohibited 0 or 1

Prohibited

CP

Specify processing to be performed when
input condition is not specified

TRAN

141

Optional

Copy destination
variable

Copy source variable

ZR

Copy

TSLP

318

Prohibited Time

Prohibited

CP

Task sleep

V

VAL

290

Optional

Variable number

Column number,
character literal

CC

Convert character string data; decimal

VALH

291

Optional

Variable number

Column number,
character literal

CC

Convert character string data; hexadecimal

VEL

192

Optional

Speed

Prohibited

CP

Set speed

VELS 193

Optional

Ratio

Prohibited

CP

Set speed ratio in PTP operation (SCARA
only)

VLMX

199

Optional

Prohibited

Prohibited

CP

Specify VLMX speed (Linear movement axis
only)

W

WGHT

227

Optional

Mass

(Inertial moment)

CP

Set tip load mass/inertial moment

WH

……

267

Prohibited Comparison variable

Comparison value

CP

Branch value [EQ, NE, GT, GE, LT, LE]

WRIT

282

Optional

Channel number

Column number

CC

Output to channel

WS

……

268

Prohibited Column number

Column number,
character literal

CP

Branch character string [EQ, NE]

WT

……

161

Optional

I/O, flag

(Wait time)

TU

Wait for I/O, flag [ON, OF]

WZFA

276

Optional

Zone number

Axis pattern

CP

Wait for zone OFF, with AND (Linear
movement axis only)

WZFO

277

Optional

Zone number

Axis pattern

CP

Wait for zone OFF, with OR (Linear
movement axis only)

WZNA

274

Optional

Zone number

Axis pattern

CP

Wait for zone ON, with AND (Linear
movement axis only)

WZNO

275

Optional

Zone number

Axis pattern

CP

Wait for zone ON, with OR (Linear movement
axis only)

Advertising
This manual is related to the following products: