Part 2 Operation

3. Drive Source Recovery Request and Operation Pause Reset Request

(1) Drive source recovery request

[1] How to request a drive source recovery

A drive source recovery request can be issued using one of the following methods:
x Set I/O parameter No. 44 to “1” (Input selection function 014 = Drive-source cutoff reset

input), then input the ON edge to input port No. 14.

x Select [Drive Source Recovery Request (P)] from the [Controller (C)] menu on the PC

software screen.

x Select Ctl (controller operation) and RPwr (drive source recovery request) on the mode

selection screen of the teaching pendant.

[2] Case where a drive source request is required

A drive source recovery request is required in the following case:
x A drive-source cutoff factor occurred when I/O parameter No. 44 was set to “1” o Recovery

after the cutoff factor is removed.

(2) Operation pause reset request

[1] How to request an operation pause reset

An operation pause reset request can be issued using one of the following methods:
x Set I/O parameter No. 35 to “1” (Input selection function 005 = Operation-pause reset signal),

then input the ON edge to input port No. 5.

x Select [Operation Pause Reset Request (L)] from the [Controller (C)] menu on the PC

software screen.

x Select Ctl (controller operation) and RAct (operation pause reset request) on the mode

selection screen of the teaching pendant.

[2] Cases where an operation pause reset request is required

An operation pause reset request is required in any of the following cases:
x An emergency stop was actuated during automatic operation when other parameter No. 10

was set to “2” (Emergency stop recovery type = Continued operation, and only during
automatic operation)

o Recovery (reset of operation pause) after the emergency stop is

reset.

x The automatic operation was stopped using the deadman switch or enable switch when other

parameter No. 11 was set to “2” (Deadman/enable switch recovery type = Continued
operation) (only during automatic operation)

o Recovery (reset of operation pause) after the

stop is reset.

x An OFF input signal was received by input port No. 6 when I/O parameter No. 36 was set

to ”1” (Input selection function 006 = Operation pause signal)

o Recovery (reset of operation

pause) after an ON-level input signal is received by input port No. 6.

* If the case in 2 of (1) and any of the cases in 2 of (2) are present at the same time, a drive

source recovery request must be issued first, followed by an operation pause reset request.