IAI America XSEL-QX User Manual
Page 214
Advertising
190
Part 4 Commands
z GACC (Get acceleration data)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional
GACC
Variable
number
Position
number
CP
[Function]
Obtain acceleration data from the acceleration item in the position data specified in operand
2, and set the value in the variable specified in operand 1.
[Example 1]
GACC
100
10
Set the acceleration data at position No. 10 in variable
100.
If the position data is set as above when the command is executed, 0.8 will be set in variable 100.