502

Appendix

(In the pan

el wind

ow, the thre

e digits aft

er “E” in

dicate an erro

r nu

mber.

)

Error No.

Error name

Description, ac

tion, etc.

C05

Program first-step BGSR error

T

he program specified for ex

ecution starts

w

ith BGSR.

C06

Exec

utable step non-

detection error

T

he program specified for

ex

ecution does n

o

t contain e

xecut

able

progr

am steps.

C07

Subro

utine n

o

n

-definiti

on err

or

T

he subr

outine

specifie

d for call is not d

e

fine

d.

C08

Subroutine duplicate-definiti

on error

T

he same

subroutine number is defined at multipl

e loc

ations.

C0A

T

ag duplicate-

definiti

on err

or

T

he same tag numb

er is defi

ned at multi

ple

locatio

ns.

C0B

T

ag non-definition error

T

he tag specified as the jum

p destinati

on of

a GOT

O statement is not defi

ned.

C0C

DW/IF/IS/SL pair-end mismat

ch error

T

he branching command s

y

nt

ax is

invalid. Correspondence

w

ith the last appearing

branc

hing com

mand is invalid

w

h

en EDIF, EDDO or EDSL is used. Check

the

correspondenc

e bet

w

e

en IF/IS command and

EDIF, DO co

mmand and E

DDO or SLCT

command and EDSL.

C0D

DW/IF/IS/SL no pair-end err

or

EDIF, EDDO o

r EDSL is

not found. Check the correspondence bet

w

e

en I

F

/IS command

and EDIF, DO command

and

EDDO or SLCT command and EDSL.

C0E

BGSR no pair-

end err

or

T

here is no EDSR for BGSR,

or no BGSR for EDSR. Check

the correspondenc

e bet

w

e

en

BGSR and EDSR.

C0F

DO/IF/IS over-nesting error

T

he number of nests in a

DO or IF/IS comm

and ex

c

eeds the limit value. Check for

exc

essive

nesti

ng or bra

nchi

n

g out of or

into

the s

y

ntax

using a GOT

O command.

C10

SLCT

over-nes

ting error

T

he number of nests in a SL

C

T

command e

xceeds the l

imit value. C

heck for exc

essiv

e

nestin

g or bran

ching

out of or into

the s

y

ntax

using

a GOT

O

command.

C11

Subroutine ov

er-nesting

error

T

he number of nests in a subroutin

e e

x

cee

ds

the limit valu

e. Check for e

x

c

e

ssive n

e

sting

or branc

hing out of or into the s

y

ntax

us

ing a GOTO command.

C12

DO/IF/IS under

-nesting error

T

he EDIF or E

DDO position is invalid. Chec

k

the correspondence bet

w

e

en IF/IS comma

nd

and EDIF or D

O

command and EDDO, or branchi

ng out of or into the s

y

ntax usi

ng a

GOT

O command.

C13

SLCT

under-nesting err

or

T

he EDSL posi

tion is inv

ali

d. Check the corr

espondence bet

w

een SLCT

and EDS

R, or

branc

hin

g out of or into the

syntax

using a GOT

O command.

C14

Subroutine under-nesting error

T

he EDSR position is inv

a

lid. Check the corr

espondence bet

w

een BGSR and EDS

R, or

branc

hin

g out of or into the

syntax

using a GOT

O command.

C15

SLCT

next-step command code error

T

he program step next to SLCT must be WH

EQ, W

HNE,

WHGT, WHGE

,

WHLT

, WHLE,

WSEQ,

WSNE, OT

HE or ED

SL.

C16

Create stack failed

Initializ

at

ion of the input-condi

tion-st

atus stor

age stuck has f

a

ile

d.

C17

Extension-condition c

ode err

or

Input progr

am step

error. T

he extension condition c

ode is i

n

vali

d.

C18 Extension-condition

LD

simul

taneous processing ov

er

error

T

he number of LDs proc

essed simultaneous

ly

ex

ceeds the l

imit value.

C19

Extension-condition

LD short

age err

or 1

T

here is not enoug

h LD

w

h

en

exte

nsi

on con

d

ition A or O is used.

C1A

Extension-condition

LD short

age err

or 2

T

here is not enoug

h LD

w

h

en

exte

nsi

on con

d

ition AB or OB is used.

Advertising