226

Part 4 Commands

z GTIF (Dedicated SCARA command: get definition coordinates of simple interference check zone)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

GTIF

Interference

check zone

number

Position number

(Consecutive two

positions will be used)

CP

[Function]

Set the definition coordinate data for the simple interference check zone specified in
operand 1 in the consecutive two position data starting from the position number specified
in operand 2.
Definition coordinates 1 of the simple interference check zone will be set in the position
data specified in operand 2, while definition coordinates 2 will be set in the next position
data. The coordinate data in the position data will include the specified definition coordinate
data for simple interference check zone after all axes are set invalid.

(Note 1)

The simple interference check zone is a dedicated SCARA function.

(Note 2)

When this command is executed, the position data for axis 5 and subsequent axes will be
cleared. Accordingly, do not specify any position currently used in linear movement axis
operation.

(Note 3)

The definition coordinates of simple interference check zone are always treated as data on
the base coordinate system (load coordinate system No. 0). Therefore, position data set via
a GTIF command must be handled on the base coordinate system.

(Note 4)

GRP commands are invalid with respect to this command.