Pnp specification, Caution – IAI America XSEL-QX User Manual

Page 64

Advertising
background image

40

Part 1 Installation

2.2. PNP

Specification

(1) Input

part

External Input Specifications (PNP Specification)

Item

Specification

Input voltage

24 VDC

r10%

Input current

7 mA per circuit

ON/OFF voltage

ON voltage --- 8 VDC max.
OFF voltage --- 19 VDC min.

Insulation method

Photocoupler insulation

External devices

[1] No-voltage contact (minimum load of approx. 5 VDC/1 mA)
[2] Photoelectric/proximity sensor (PNP type)
[3] Sequencer transistor output (open-collector type)
[4] Sequencer contact output (minimum load of approx. 5 VDC/1 mA)

[Input circuit]

* N: I/O interface pin No. 50

Caution

If a non-contact circuit is connected externally, malfunction may result from leakage
current. Use a circuit in which leakage current does not exceed 1 mA.

~ X-SEL controller’s input signal

At the default settings, the system recognizes the ON/OFF durations of input signals if they
are approximately 4 msec or longer. The ON/OFF duration settings can also be changed
using I/O parameter No. 20 (input filtering frequency).

Internal cir

cuit

Input terminal

External power
supply 24 VDC

10%

N*

560

:

3.3 K

:

ON duration

OFF duration

+

-