I/o parameters – IAI America XSEL-QX User Manual

Page 451

Advertising
background image

427

Appendix

1. I/O

Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

1

I/O port assignment type

1

0 ~ 20

0: Fixed assignment
1: Automatic assignment (Priority: Network I/F module >

Slot 1 (standard I/O) ~ * Ports are assigned only for
the installed adjoining slots, starting from slot 1 = For
safety reasons)

2

Input port start number
with fixed standard I/O
assignments (I/O1)

000

-1 ~ 599

0 + (Multiple of 8) (Invalid if a negative value is set)

3

Output port start number
with fixed standard I/O
assignments (I/O1)

300

-1 ~ 599

300 + (Multiple of 8) (Invalid if a negative value is set)

4

Input port start number
with fixed expanded I/O1
assignments (I/O2)

-1

-1 ~ 599

0 + (Multiple of 8) (Invalid if a negative value is set) (Slot
next to the standard I/O slot)

5

Output port start number
with fixed expanded I/O1
assignments (I/O2)

-1

-1 ~ 599

300 + (Multiple of 8) (Invalid if a negative value is set)

6

Input port start number
with fixed expanded I/O2
assignments (I/O3)

-1

-1 ~ 599

0 + (Multiple of 8) (Invalid if a negative value is set)

7

Output port start number
with fixed expanded I/O2
assignments (I/O3)

-1

-1 ~ 599

300 + (Multiple of 8) (Invalid if a negative value is set)

8

Input port start number
with fixed expanded I/O3
assignments (I/O4)

-1

-1 ~ 599

0 + (Multiple of 8) (Invalid if a negative value is set)

9

Output port start number
with fixed expanded I/O3
assignments (I/O4)

-1

-1 ~ 599

300 + (Multiple of 8) (Invalid if a negative value is set)

10 Standard I/O error monitor

(I/O1)

1

0 ~ 5

0: Do not monitor
1: Monitor
2: Monitor (Do not monitor 24-V I/O power-supply

errors)

3: Monitor (Monitor 24-V I/O power-supply errors only)
* Some exceptions apply.
* If 0 (= Do not monitor) or 2 (= Monitor (Do not monitor

24-V I/O power-supply errors)) is selected, a system
error will not generate when a 24-V I/O power-supply
error occurs. To protect the controller, however, the
actual outputs of the digital I/O board will be cut off by a
circuit later.

11 Expanded I/O1 error

monitor (I/O2)

1

0 ~ 5

0: Do not monitor
1: Monitor
2: Monitor (Do not monitor 24-V I/O power-supply

errors)

3: Monitor (Monitor 24-V I/O power-supply errors only)
* Some exceptions apply.
(Slot next to the standard I/O slot)
* If 0 (= Do not monitor) or 2 (= Monitor (Do not monitor

24-V I/O power-supply errors)) is selected, a system
error will not generate when a 24-V I/O power-supply
error occurs. To protect the controller, however, the
actual outputs of the digital I/O board will be cut off by a
circuit later.

12 Expanded I/O2 error

monitor (I/O3)

1

0 ~ 5

0: Do not monitor
1: Monitor
2: Monitor (Do not monitor 24-V I/O power-supply

errors)

3: Monitor (Monitor 24-V I/O power-supply errors only)
* Some exceptions apply..
* If 0 (= Do not monitor) or 2 (= Monitor (Do not monitor

24-V I/O power-supply errors)) is selected, a system
error will not generate when a 24-V I/O power-supply
error occurs. To protect the controller, however, the
actual outputs of the digital I/O board will be cut off by a
circuit later.

Advertising