No.

Parameter name

Default value

Input range

Unit

202

Attribute 2 of SIO channel 1 opened to user
(mount standard)

00000001H

0H to FFFFFFFFH

None

214

Attribute 2 of SIO channel 2 opened to user
(mount standard)

00000001H

0H to FFFFFFFFH

None

z Set Values

Bits 28 to 31:

For future extension

Bits 24 to 27:

Reserved by the system.

Bits 20 to 23:

Reserved by the system.

Bits 16 to 19:

Character send interval (msec)

Bits 12 to 15:

Communication method (0: Full-duplex, 1: Half-duplex)

Bits 8 to 11:

Send operation type in half-duplex communication
(0: Do not check CTS-ON at send
1: Check CTS-ON at send)

Bits 0 to 7:

Minimum receive

o send switching delay in half-duplex communication (msec)

No.

Parameter name

Default value

Input range

Unit

203

Attribute 3 of SIO channel 1 opened to user
(mount standard)

01118040H

0H to FFFFFFFFH

None

215

Attribute 3 of SIO channel 2 opened to user
(mount standard)

01118040H

0H to FFFFFFFFH

None

z Set Values

Bits 28 to 31:

Flow control type
(0: None, 1: Xon/Xoff, 2: Hardware)
* Valid only in full-duplex communication.
* If flow control is performed, select 38.4 kbps or less. Specifying a higher baud rate

may generate an overrun error, etc.

Bits 24 to 27:

Xon send selection when send after SIO-CPU reset is enabled
(0: Do not send, 1: Send)
* Valid only in full-duplex communication with Xon/Xoff flow control.

Bits 20 to 23:

Send enable selection when the port is open
(0: Disable, 1: Enable)
* Valid only in full-duplex communication with Xon/Xoff flow control.

Bits 16 to 19:

Xon/Xoff send selection when the port is closed
(0: Do not send, 1: Send Xon, 2: Send Xoff)
* Valid only in full-duplex communication with Xon/Xoff flow control.

Bits 8 to 15:

Flow control high limit (byte)

Bits 0 to 7:

Flow control low limit (byte)
* If the specified value satisfies the condition “Flow control low limit

t SCI receive

buffer size – flow control high limit,” both the flow control high limit and low limit will
be replaced by values corresponding to 1/4 of the SCI receive buffer size before the
applicable processing is performed.